Three-phase unbalanced intelligent regulating device

The three-phase unbalanced intelligent regulating device of distribution network is a device which uses IGBT technology,SVG Technology,power electronics technology and other technologies.The SVG series static var generator is a,which parallel connected the voltage source inverter to the power grid by a reactor.The voltage source inverter consists of DC capacitor and inverter bridge,in which the inverter bridge consists of a semiconductor device IGBT which can be turned off

Category:

Three-phase unbalanced series

key word:

regulating

device

current

power

inverter

reactive


Online Message

Product Description

■ Product profile
The three-phase unbalanced intelligent regulating device of distribution network is a device which uses IGBT technology,SVG Technology,power electronics technology and other technologies.The SVG series static var generator is a,which parallel connected the voltage source inverter to the power grid by a reactor.The voltage source inverter consists of DC capacitor and inverter bridge,in which the inverter bridge consists of a semiconductor device IGBT which can be turned off.
 
■ Model description
 
  SEFON
 
■ Configuration & working principle
The three-phase unbalanced intelligent regulating device can analyze the three-phase load imbalance situation according to the AC sampling of the sampling circuit when power on,calculate the current value and phase to be compensated,send the signal to IGBT by the signal generator,and send a current signal to the system by the inverter to meet the requirements,so as to realize the three-phase load balance regulation.
 
The device can realize inductive and capacitive bidirectional dynamic reactive power tracking compensation by adjusting the remaining capacity of the device after three-phase imbalance,detect the load current in real time,analyze the reactive power capacity of the load current by DSP calculation,control the signal generator according to the set compensation range,output the signal to IGBT drive circuit,and make the inverter to generate reactive current which is equal to the reactive component and in opposite direction of the system,so as to achieve the purpose of real-time dynamic tracking compensation reactive power.
 
  SEFON
 
■ Product features
● Three phase imbalance regulation,two-way reactive power regulation and voltage regulation.
 
● Real-time compensation,the response time is less than 15ms.
 
● Current source device,no resonance,no harmonic.
 
● Small self loss and small floor area.
 
● Safety operation,design service life is more than 20 years.
 
● Maintenance free design,complete protection function and labor cost saving;
 
● Modular design,easy to install and debug;
 
● With standard WiFi module can directly check the device operation in a short distance.
 